• Product Description
  • Contact Us
  • Valves
    • Solenoid Valves
    • Pneumatic Valve
    • Manual Valve
  • F.R.L.
  • Cylinders
  • Fittings
  • Vacuum
    • Vacuum
    • Vacuum Filter
  • Pressure Sensor
  • Others
    • Mufflers
Home  >  Product Description  >  Pressure Sensor  >  NP90
Pressure Sensor
NP90
  • NP90

 

 

 

 

Model Description:

NP90 Series Specifications:

Model NP90V-010-M5 (Negative Pressure)
Rated Pressure Range -100.0 ~ 100.0 kPa 0.0 ~ -101.3 kPa 0.000 ~ -1.000 kPa
Set Pressure Range -101.0 ~ 101.0 kPa 10.0 ~ -101.3 kPa -0.100 ~ 1.000 kPa
Pressure Resistant 500 kPa 1.5 kPa
Rated Pressure Range 0.000 ~ 1.000 MPa 0.0 ~ -101.3kPa
Applicable Gas Air, non-corrosive, non-flammable
Pressure Unit
Set Minimum Scale
kPa 0.1 -
MPa - 0.001
kgf/cm2 0.001 0.01
bar 0.001 0.01
psi 0.01 0.1
inHg 0.1 -
mmHg 1 -
Voltage 12 to 24V DC ± 10%, Ripple Peak 10% The Following
Current Consumption ≦40mA (When No Load)
Switch Output
NPN Open Collector Output
Maximum Load Current:125mA
Maximum Supply Voltage:30V DC
Internal Pressure Drop:≦1.5V
  PNP Open Collector Output
Maximum Load Current:125mA
Maximum Supply Voltage:24VDC
Internal Pressure Drop:≦1.5V
Repeat Accuracy ± 0.2% F.S. ± 1 digit
Response Hysteresis Mode Adjustable
Window Compare Mode Fixed (3 digits)
Reaction Time ≦2.5ms(Malfunction Prevention Function:
25ms, 100ms, 250ms, 500ms,
1000ms and 1500ms Optional)
Output Short Circuit Protection Have
Show 4 Digits, 7 Segment Display (Red)
Display Accuracy ±2%,F.S. ±1digit(At Ambient Temperature:25±3℃)
Action Indicator OUT1 Red / OUT2 Green
Linear Analog Output
(Voltage Output)
The Output Voltage:
1.5V±2.5% F.S.(Under Rated Pressure)
Linearity:±1% F.S.
Output Resistance:About 1kΩ
Environment
Resistant
Protection
Structure Level
IP40
Ambient
Temperature
Action:0~50℃, Save:-10~60℃
(Under The Condition Of No Dew And No Freezing)
Ambient Humidity Action and Save:35~85% RH
(No Water Dew)
Withstand voltage 1000V AC 1 Minute
(Between Lead And Case)
Insulation Resistance 50MΩ Above(500V DC)
(Between Lead And Case)
Vibration Resistant Complex amplitude 1.5mm or 10G,
10Hz~150Hz per minute,
2 hours in each direction of X, Y and Z
Shock Proof 980m/s2(100G), X、Y、Z 3 times in each direction
Temperature
Characteristics
±2% F.S. (0~50 Temperature Range)
Takeover Diameter M5
Wire Gauge Oil Resistant PVC Wire(0.14mm2)
Weight About 53g (including 2 meters of wire)
Back to previous page